SKU: 13-521-108

Straight Cut B - Ti 14" .036 - PK/10

  • 14 inch ( 35.50 cm) length.
  • Each wire may form 2-3 arches.
  • Great formability with an excellent range of activation
  • Provides SS bendability and NiTi flexibility.
  • Moderate force between SS and regular NiTi.
  • Detailing could be easily achieved in the ?nal stage of treatment
Products specifications
Attribute nameAttribute value
MSDS04-14-0003 V5.20 Beta-Titanium wire
Customers who bought this item also bought

Open Coil NiTi .010 × .045 - 15" - Spool/15'

- NiTi delivers gentle consistent force for reliable results. Great for pain sensitive patients

Limber, Copper NiTi Broad Form Upper .013 - 27° - PK/10

- A true super elastic wire with thermo elastic shape memory. - Generates more consistent tooth movement as the wire is active longer in the optimal force range. - Offered in multiple transformation temperatures to provide the right wire for your unique case. - The higher the temperature transition (TTR), the lower the relative forces delivered by the wire. - The lighter forces exhibited by the copper nickel titanium and its high flexibility, allow these wires to be engaged in cases with moderate to severe tooth to tooth misalignment. - Longer clinical activation promotes reduced chair time and greater durations between wire changes. - Independent testing has shown that the copper nickel titanium wire demonstrates maximum unraveling of crowding over a period of time, when compared to nickel titanium and stainless steel. - The addition of copper has been known to increase corrosive resistance and control the hysteresis width - Use 27°C Copper when higher force levels are needed

Limber, Copper NiTi Broad Form Upper.014 - 27° - PK/10

- A true super elastic wire with thermo elastic shape memory. - Generates more consistent tooth movement as the wire is active longer in the optimal force range. - Offered in multiple transformation temperatures to provide the right wire for your unique case. - The higher the temperature transition (TTR), the lower the relative forces delivered by the wire. - The lighter forces exhibited by the copper nickel titanium and its high flexibility, allow these wires to be engaged in cases with moderate to severe tooth to tooth misalignment. - Longer clinical activation promotes reduced chair time and greater durations between wire changes. - Independent testing has shown that the copper nickel titanium wire demonstrates maximum unraveling of crowding over a period of time, when compared to nickel titanium and stainless steel. - The addition of copper has been known to increase corrosive resistance and control the hysteresis width - Use 27°C Copper when higher force levels are needed

Limber, Copper NiTi Broad Form Upper.016 - 27° - PK/10

- A true super elastic wire with thermo elastic shape memory. - Generates more consistent tooth movement as the wire is active longer in the optimal force range. - Offered in multiple transformation temperatures to provide the right wire for your unique case. - The higher the temperature transition (TTR), the lower the relative forces delivered by the wire. - The lighter forces exhibited by the copper nickel titanium and its high flexibility, allow these wires to be engaged in cases with moderate to severe tooth to tooth misalignment. - Longer clinical activation promotes reduced chair time and greater durations between wire changes. - Independent testing has shown that the copper nickel titanium wire demonstrates maximum unraveling of crowding over a period of time, when compared to nickel titanium and stainless steel. - The addition of copper has been known to increase corrosive resistance and control the hysteresis width - Use 27°C Copper when higher force levels are needed